🔮Madjik

Liquidity Fragmentation Index (M50008)

Metric IDM50008
Categoryvolume
Accesspublic
Classificationclassic
Tierbasic
ComputationClassical + Quantum (hardware) + Quantum (simulated)
Computed byBlack Belt Labs
Freshnessfresh

Quantum configuration

Every quantum calculation of this metric, with the machine and circuit setup it runs on. Hardware values come from real IBM quantum computers; simulator values from a classical simulation of the same kind of circuit.

MethodQuantum computing on hardware (quant-hw)
ProviderIBM Quantum Platform (Open plan)
Machineibm_marrakesh (156 qubits)
Machine typesuperconducting QPU (IBM Heron)
Qubits used4
Circuits per run16
Shots per run65,536
Circuit depth9
Two-qubit gates2
Gate basiscz, rz, sx, x (IBM Heron native)
Algorithmtwo-copy collision test (purity of the venue-depth-share state), repeated 8x and averaged
Profilefull
Error mitigationdynamical decoupling + measurement twirling; no post-hoc correction
Hardware runs2
Last run2026-10-05T06:31:07
IBM job iddb1k39uegvvc73bho95g
How measuredIBM job record (transpiled circuit stats)
MethodQuantum computing simulated (quant-sim)
ProviderQiskit Aer simulator (IBM open-source software) on Google Cloud
Machineaer_simulator
Machine typeclassical simulator (CPU, noise-free)
Qubits used4
Circuits per run16
Shots per run65,536
Circuit depth4
Two-qubit gates2
Gate basisu, cx (Aer, flattened)
Algorithmtwo-copy collision test (purity of the venue-depth-share state), repeated 8x and averaged
Profilefull
Error mitigationnone (noise-free simulation)
How measuredrecorded circuits, compiled to u/cx

Personal metrics: figures are the maximum across submitted portfolios (circuit size follows portfolio size). Machine qubits is the size of the whole chip; qubits used is what this calculation needs.

Method comparison (experimental)

The same metric computed several ways on the same frozen inputs, one change at a time, so a gap between two rows has a known cause. Each plus/minus is the standard error of that value. How to read this, and how it scales.

Daily simulator-only comparison

Snapshot 20261008T1300_79c20e7d · 2026-10-08 13:00 UTC

StepMethodValue
Classical, exactclassical99.1
Production value (-0.0 h from the snapshot)classical99.1
Quantum simulator, idealquantum simulated99.1
Quantum simulator, sampledquantum simulated99.1 ± 0.2542
Noisy device modelquantum simulated99.4 ± 0.2627

Quantum values are not expected to beat the classical value at these problem sizes. The purpose of this section is to show, with uncertainty, how and why the methods differ. Small samples: treat scores as indicative.

Hypotheses monitored by this metric

Access this metric

Query it via the Madjik API:

curl -H "X-API-Key: $MADJIK_API_KEY" \
  https://api.madjik.io/v1/metrics/M50008

🚀 Get API Access Now   API documentation