🔮Madjik

Crash-Skew Premium (M10072)

Metric IDM10072
Categoryderivatives
Accesspublic
Classificationclassic
ComputationClassical + Quantum (hardware) + Quantum (simulated)
Computed byBlack Belt Labs
Freshnessfresh
Last refreshed

Calculation methods

MethodLast refreshed
Classical
Quantum (simulated)
Quantum (hardware)

Quantum configuration

Every quantum calculation of this metric, with the machine and circuit setup it runs on. Hardware values come from real IBM quantum computers; simulator values from a classical simulation of the same kind of circuit.

MethodQuantum computing on hardware (quant-hw)
ProviderIBM Quantum Platform (Open plan)
Machineibm_marrakesh (156 qubits)
Machine typesuperconducting QPU (IBM Heron)
Qubits used4
Circuits per run2
Shots per run16,384
Circuit depth83
Two-qubit gates21
Gate basiscz, rz, sx, x (IBM Heron native)
Algorithmdirect amplitude readout on hardware (shallow profile)
Profileshallow
Error mitigationdynamical decoupling + measurement twirling; no post-hoc correction
Hardware runs2
Last run2026-10-05T06:30:30
IBM job iddb1k3gpb694s73dsd7kg
How measuredIBM job record (transpiled circuit stats)
MethodQuantum computing simulated (quant-sim)
ProviderQiskit Aer simulator (IBM open-source software) on Google Cloud
Machineaer_simulator
Machine typeclassical simulator (CPU, noise-free)
Qubits used6
Circuits per run10
Shots per run40,960
Circuit depth2471
Two-qubit gates1403
Gate basisu, cx (Aer, flattened)
AlgorithmMaximum-likelihood quantum amplitude estimation, two runs (puts, calls)
Profilefull
Error mitigationnone (noise-free simulation)
How measuredrecorded circuits, compiled to u/cx

Personal metrics: figures are the maximum across submitted portfolios (circuit size follows portfolio size). Machine qubits is the size of the whole chip; qubits used is what this calculation needs.

Method comparison (experimental)

The same metric computed several ways on the same frozen inputs, one change at a time, so a gap between two rows has a known cause. Each plus/minus is the standard error of that value. How to read this, and how it scales.

Daily simulator-only comparison

Snapshot 20261016T0003_fc188bac · 2026-10-16 00:03 UTC

StepMethodValue
Classical, exactclassical3.288
Production value (-0.1 h from the snapshot)classical3.27
Quantum simulator, idealquantum simulated3.29
Quantum simulator, ideal (hardware-sized circuit)quantum simulated3.29
Quantum simulator, sampledquantum simulated3.29 ± 0.02129
Noisy device modelquantum simulated3.08 ± 0.02345

Quantum values are not expected to beat the classical value at these problem sizes. The purpose of this section is to show, with uncertainty, how and why the methods differ. Small samples: treat scores as indicative.

Access this metric

Query it via the Madjik API:

curl -H "X-API-Key: $MADJIK_API_KEY" \
  https://api.madjik.io/v1/metrics/M10072

🚀 Get API Access Now   API documentation